Customization: | Available |
---|---|
Breaking Capacity: | High |
Type: | Current Fuse |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Principle and Function of Fuse Cut Out
The high-voltage drop-out fuse consists of three parts: insulating support, dynamic and static contacts, and fuse tube. The static contacts are installed at both ends of the insulating support, and the fuse tube is composed of an inner arc suppression tube and an outer phenolic paper tube or epoxy glass fiber cloth tube.
Drop-out fuses are suitable for power systems with a frequency of 50/60Hz and a rated voltage of 35KV and below, and are installed on the high-voltage side of distribution transformers or on the main lines of distribution. The main function is where the protection performance is not high, it can be used in conjunction with the isolating switch to replace the automatic air switch; it can also be used in conjunction with the load switch to replace the expensive circuit breaker. It also has short circuit protection, overload and isolation circuits.
Electric Fuse Switch General
1.Made of high quality material, it has long service life. The fusant is made of pure copper strip. The fusion tube is made of high strength china. The extinguishing medium is made of pure quartz sand.
2.Easy installation and maintenance. The terminal of fusant contacting with the end-plate (or the connecting plate) use the technology of spot welding.
3.Safe indication. The fuse with the indicator can be show the fusing when the indicator pop-up.
4.Durable and reliable
Electric Fuse Switch Service Conditions
Environment temperature:-40ºC to 40ºC.
Relative humidity:daily average value not more than 95%, on average less than 90%.
The location of on more than 1000m altitude(high altitude type not more than 3000m).
Wind speed not more than 34m/s.
Ice cover thickness not more than 20mm.
Installation site should be no fire and explosion danger, chemical corrosion and strenuous vibration.
Technical Parameter Table
Type | Unit | JDOP12100C320 | JDOP12200C320 |
Rated Voltage | KV | 15 (24) | 15 (24) |
Rated Current | A | 100 | 200 |
Rated Short-circuit Breaking Current | KA | 10 | 10 |
Impulse Withstand Voltage (BIL) | KV | 125 | 125 |
Power Frequency withstand Voltage | KV | 50 | 50 |
Creepage Distance | mm | 320 | 320 |
Weight | kg | 8 | 8.5 |
Applicable Standard | IEC 60282-2 | IEC 60282-2 | |
Package Size | cm | 51*38.5*39.2=3pcs | 51*38.5*39.2=3pcs |
Product Details
Application of Cutouts