Expulsion Dropout 33kv T Bar Type Fuse Cut out

Product Details
Customization: Available
Breaking Capacity: High
Type: Current Fuse
Manufacturer/Factory, Trading Company
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
101~500 square meters
Management System Certification
ISO 9001
  • Expulsion Dropout 33kv T Bar Type Fuse Cut out
  • Expulsion Dropout 33kv T Bar Type Fuse Cut out
  • Expulsion Dropout 33kv T Bar Type Fuse Cut out
  • Expulsion Dropout 33kv T Bar Type Fuse Cut out
  • Expulsion Dropout 33kv T Bar Type Fuse Cut out
  • Expulsion Dropout 33kv T Bar Type Fuse Cut out
Find Similar Products

Basic Info.

Model NO.
DOPT33660
Usage
High Voltage
Shape
Circle
Fusing Speed
FF
Fusing Device
Pop-up Solid
Standard
IEC
Transport Package
Carton Box
Specification
JDO
Trademark
Jecsany
Origin
China
HS Code
8535100000
Production Capacity
20000PCS/Year

Product Description

 

Principle and Function of Fuse Cut Out
The high-voltage drop-out fuse consists of three parts: insulating support, dynamic and static contacts, and fuse tube. The static contacts are installed at both ends of the insulating support, and the fuse tube is composed of an inner arc suppression tube and an outer phenolic paper tube or epoxy glass fiber cloth tube.

Drop-out fuses are suitable for power systems with a frequency of 50/60Hz and a rated voltage of 35KV and below, and are installed on the high-voltage side of distribution transformers or on the main lines of distribution. The main function is where the protection performance is not high, it can be used in conjunction with the isolating switch to replace the automatic air switch; it can also be used in conjunction with the load switch to replace the expensive circuit breaker. It also has short circuit protection, overload and isolation circuits.

Technical Parameter Table
 

Type Unit DOPT33660-100 DOPT33660-200
Rated Voltage KV 36 36
Rated Current A 100 200
Rated Short-circuit Breaking Current KA 6 6
Impulse Withstand Voltage (BIL) KV 170 170
Power Frequency withstand Voltage KV 70 70
Creepage Distance mm 660 660
Weight kg 12 12.5
Applicable Standard    IEC 60282-2 IEC 60282-2
Package Size cm 60*35*17.5 60*35*17.5


Product Details
Expulsion Dropout 33kv T Bar Type Fuse Cut outExpulsion Dropout 33kv T Bar Type Fuse Cut outExpulsion Dropout 33kv T Bar Type Fuse Cut outExpulsion Dropout 33kv T Bar Type Fuse Cut outExpulsion Dropout 33kv T Bar Type Fuse Cut out






Application of Cutouts
Expulsion Dropout 33kv T Bar Type Fuse Cut out

 