Plant Area
101~500 square meters
Management System Certification
ISO 9001
  • Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
  • Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
  • Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
  • Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
  • Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
  • Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
Overview

Basic Info.

Model NO.
JDOS241C750
Installation
Circuit Board Type
Shape
Circle
Size of Fuse
Medium Fuse Holder
Environmental Protection
Environmental Protection Fuse Holder
Execution Standard
National Standard
Fusing Speed
K, T, H
Brand
Jecsany
Accessories
NEMA Bracket, Fuse Link, Arc Shortening Rod
Rated Voltage
33-36kv
Rated Current
100A, 200A
Function
Over-Current Protection
Transport Package
Cartons
Specification
JDOS241C750
Trademark
Jecsany
Origin
Zhejiang, China
HS Code
8535100000
Production Capacity
50000PCS/Year

Product Description

Product Description

fuse cutouts

Drop-out fuse cutout and load switching fuse cutouts are outdoor high voltage protection device. They are connected with the Incoming feeder of the distribution transformer or distribution lines. These are primary used to protect transformers or lines from short circuits and overloads and switching currents. The drop-out fuse unit is composed of insulator supports and a fuse tube, static contacts is fixed on two sides of Insulator support and moving contact Is installed on two ends of fuse tube. The interior of the fuse tube is the extinguishing tube, the exterior is made of phenolic compound paper tube or epoxy glass. Load switching cutout fuse provides stretch auxiliary contacts and arc-extinguishing ex-closure for switching on/off loading current.

In normal operation the fuse link is tightened to form the closed position. In fault current situation, the fuse link melts and an electrical arc is formed. The arc -extinguishing tube Is heated and explosion of gas occurs. This causes high pressure inside the tube and cause the tube to separate from the contacts. The strength of the contact is relaxed once the fuse elements melt

The cutout is now in the open position, the operator needs to switch the current off. Then with an insulated operating bar, the moving contact can be pulled off. The main contact and auxiliary contact is connected.
Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
Product Parameters

Fuses are widely used in high and low voltage power distribution systems and control systems as well as electrical equipment. As short circuit and overcurrent protectors, they are one of the most commonly used protection devices.
It is designed to be installed outdoors for vertical cross arm or pole mounting.We manufactures the expulsion fuse cutouts in both Porcelain & Silicone rubber insulators.
Ratings: 11kV-36kV.

 

Service condition
Rated  voltage 24KV
Rated max voltage 33KV
Rated current 100A
Breaking current 10KA
Creepage distance 750mm
Impulse voltage 170BL
Power frequency withstand voltage 70KV
 
Detailed Photos
Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse CutoutOutdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
-Good selection.  (As long as the rated current of the fuse link of the upper and lower level fuses meets the requirements of the overcurrent selection ratio of 1.6:1 stipulated in the national standard and IEC standard, that is, the rated current of the upper level fuse link is not less than 1.6 times of the value of the lower level, it will be regarded as the upper and lower level fuses. Selective interruption of fault current)
-Good current limiting characteristics and high breaking capacity
-Relatively small size
- Cheaper price


More products are as follows
Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse CutoutOutdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
Company Profile

 

 

Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout

Outdoor High Voltage 33kv Polymer Electrical Expulsion Dropout Fuse Cutout
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier