Srm6-12 Full Gas Insulated Ring Main Unit (RMU)

Product Details
Customization: Available
Certification: ISO9001
Shell Material: Aluminum Alloy
Manufacturer/Factory, Trading Company
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
101~500 square meters
Management System Certification
ISO 9001
  • Srm6-12 Full Gas Insulated Ring Main Unit (RMU)
  • Srm6-12 Full Gas Insulated Ring Main Unit (RMU)
  • Srm6-12 Full Gas Insulated Ring Main Unit (RMU)
  • Srm6-12 Full Gas Insulated Ring Main Unit (RMU)
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
SRM6-12
Installation
Fixed
Structure
Cabinet
Current
AC
Color
White
Transport Package
Carton
Specification
according the request
Trademark
jecsany
Origin
China
HS Code
8535210000
Production Capacity
1000PCS

Product Description

Product Description

 



SRM6-12 Series Gas-insulated Ring Main Unit Switchgear are widely used in 10KV/20KV power distribution systems. SRM6-12 series adopts modular unit mode. Its units are divided into fixed units (non-expandable) and expandable units. These units can be assembled and combined according to different needs. By choosing an expandable bus, SRM6-12 series can be combined at will to achieve full modularity. Due to its fully modular and semi-modular features, SRM6-12 series is extremely flexible and expandable, which can meet the needs of compact switch cabinets in various substations. SRM6-12 series is a completely sealed system, all live components and circuit breaker switches are enclosed in a stainless steel body, so that the entire switchgear is not affected by external environmental conditions, thereby ensuring operational reliability and personal safety, and achieving long service life (in the rated environment, its design life exceeds 30 years) and maintenance-free.

Environmental Conditions
1.Ambient Temperature: No more than +40'ºC, No less than -40'ºC.Average temperature no more than +35'ºC within 24 hours.
2.Altitude: No more than 2000m.
3.Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.
4.Earthquake Intensity: No more than 8 deqrees.
5.Vapor Pressure: the average dally value is no more than 2.2kPa,and the average monthly value is no more than 1.8kPa6.Iinstallation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.

Product Features
1.Fuly sealed design,all 10kV switches and busbar electrified bodies are sealed in the gas box welded by 3mm stainless steel plateand the silicon rubber cable plug is applied to achieve the fullinsulaion seal of the cable head, so that it is not affected by externalenvironment such as dust, humidity and small animals.2.The switching device has a perfect "five-preventions', with simple and clear operation procedures.3.Modular design. Each unit module can be combined and extended arbitrarily, which is easy to schemes combination, with a wideapplicable range.
4.Big capacity for feeder line, small occupation, suitable for a variety of needs, wide range of applications.
5.Equipment maintenance-free, highly reliable performance.


Technical Data
Content Unit C Module F Module V Module CB Module
Load Switch Load Switch with Fuse Vacuum Switch Disconnector/Earthing Switch Vacuum Switch Disconnector/Earthing Switch
Rated Voltage kV 12
Rated Frequency Hz 50/60
Power Frequency Withstand voltage in 1 min kV 42/48
Lightning impulse Withstand voltage (Peak) kV 75/85
Rated Current A 1250/630 Note1 1250/630 - 1250/630 -
Rated Closed Loop Breaking Current A 630 - - - - -
Rated Cable Charging Breaking Current A 10 - - - - -
Rated Short Circuit Making Current A 50 80 50 50 63 63
Rated Peak Withstand Current kA 50 - 50 - 63 -
Rated Short Circuit Breaking Current kA/3S 20 - 20 - 25 -
Rated Short Circuit Breaking Current kA - 31.5 20 - 25 -
Rated Transfer Current A - 1700 - - - -
Max. Rated current of fuse A - 125 - - - -
Loop Resistance μΩ ≤300 ≤600        
Mechanical Life times 5000 3000 5000 2000 5000 5000
                 

Typical Scheme Diagram
Srm6-12 Full Gas Insulated Ring Main Unit (RMU)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier