• Lw8a-40.5 2000A Voltage AC Sf6 Circuit Breaker
  • Lw8a-40.5 2000A Voltage AC Sf6 Circuit Breaker
  • Lw8a-40.5 2000A Voltage AC Sf6 Circuit Breaker
  • Lw8a-40.5 2000A Voltage AC Sf6 Circuit Breaker
  • Lw8a-40.5 2000A Voltage AC Sf6 Circuit Breaker

Lw8a-40.5 2000A Voltage AC Sf6 Circuit Breaker

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: Lw8-40.5
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
Lw8a-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Certification
ISO9001-2000, IEC
Transport Package
Wooden Carton
Specification
LW8A-40.5 Voltage AC SF6 Circuit Breaker
Trademark
JECSANY
Origin
China
HS Code
8504220000
Production Capacity
50000PCS/Years

Product Description

Circuit Breakers & Switch /Outdoor Circuit Breakers
LW8A-40.5 Voltage AC SF6 Circuit Breaker 

Product Description
Product Description
 

 

1. LW8A-40.5 Type live tank 33kv 36kv SF6 Circuit Breaker

 

LW8A-40.5 Type live tank 33kv 36kv SF6 Circuit Breaker Is three-phases electrical system with alternating current 50HZ and the rated voltage 40.5kV.It is used for contolling and protecting the electrical system and measuring the current transformers.

 

2. Advantages

 

1.It conforms to GB1984 standard,GB/T28001-2011 idt OHSAS18001:2007,GB/T 24001-2004 idt ISO14001:200;

2.Frequent operation, each set can be installed with 12 current transformers;

3.The new sf6mkz pointer type densitometer, the pressure gauge reading is not affected by the temperature change.

 

3.  Environmental Conditions

 

The daily average saturated vapor pressure:  ≤2.2KPa;

The monthly average value:  ≤1.8KPa.

Altitude:  ≤3000m

Seismic intensity:  ≤8

Air pollution level:  Level

Ambient temperature:  -30°C~+40°C
Relative humidity:  ≤95%or≤90%

Wind pressure:  ≤700pa

The installation shall be free from fire, explosion, severe vibration, chemical corrosion and serious pollution.

 

4. Technical Parameter

 

Name Data
Rated voltage 40.5
Rated current(A) 1600/2000
Rated Insulate level Power frequency withstand voltage(kV)1min 95
Thunder impulse withstand vltage (kV) 185
Rated short-circuit breaking current(kA) 25/31.5
Rated outof-phase breaking current (kA) 7.9/10
breaking current of earth fault in different phase(kA) 27.4/34.8
Rated breaking current of single capacitor bank(A) 400
Rated Operating sequence O-0.3S-CO-180S-CO
Rated SF6 gas pressure(Mpa) 0.5
Switch-off time(on rated voltage)(ms) 30≤t≤40
Switch-on time(on rated voltage)(ms) 60≤t≤80
Rated short-circuit making current(peak) (kA) 63/80
Rated short-circuit duration (s) 4
Rated short-circuit with stand current (kA) 25/31.5
Rated peak value withstand current(kA) 63/80
Mechanical life (time) 10000

Cumulative breaking times of rated short-circuit

breaking current 31.5 kA/40kA(time)

20
Cumulative breaking times of rated current(time) 2000
Annual leakAge rate of SF6(%) ≤0.5
Water content of SF6(VV)(PPm) ≤150
Outer insulating leakAge ratio distance(mm/kV) ≥25,≥31
Weight of the circuit breaker(KG) 1000