• 12kv Auto 3 Phase Sf6 Gas Circuit Breaker
  • 12kv Auto 3 Phase Sf6 Gas Circuit Breaker
  • 12kv Auto 3 Phase Sf6 Gas Circuit Breaker

12kv Auto 3 Phase Sf6 Gas Circuit Breaker

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: ACB
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
ZW20-12F
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
ISO9001-2000
Transport Package
Wooden Carton
Specification
ZW20-12F
Trademark
JECSANY
Origin
China
HS Code
8504220000
Production Capacity
50000PCS/Year

Product Description

Product Description

ZW20-12 model outdoor AC vacuum circuit breaker is used to make and break load current, overload current and short-circuit current in 12kV, 50/60Hz power system. It's applicable for substations, industry and mining, urban and rural electricity power networks, especially applicable in occasions with frequent operation and automatic power distibution network. It accords with the standards of IEC62271-100 &GB1984 AC high voltage circuit breaker, GB/T 11022 HV General technical requirement of switches and control apparatus.

 

 

 

Basic equipments:

1. Current transformer protection poles 2 pieces

2. Spring mechanism AC220V

3. Surge arrester device

 

Optional equipments:

1. Current transformer, metering pole 3 pieces 200/5 or higher.

2. Outer voltage transformer 2 pierces (for control power supply and metering).

3. Motor spring mechanism AC/DC220/1 10/48/24V.

4. Reclosing controller and series FTU and RTU.

 

12kv Auto 3 Phase Sf6 Gas Circuit Breaker12kv Auto 3 Phase Sf6 Gas Circuit Breaker

Model description

 

 Technical Parameter  

Name Unit Data
Rated voltage  KV  12
Rated power frequency  Hz 50 
Rated current  KA  630/1000
Rated short-circuit breaking current KA   20/25
Rated withstand current(peak) KA   50/63
Rated short-time withstand current(4s) KA   20/25
Rated short-circuit making current(peak) KA   50/63
Mechanical life  Secondary  10000
Rated short-circuit breaking time  Secondary  30

Power frequency withstand voltage

(1min) :( wet) (dry) white, right\fracture

 KV  42/48

Lighting impulse withstand votage

(peak) and white, right \ fracture

 KV  75/85

Secondary circuit 1min power

frequency withstand voltage

 KV  2

Weight

kg 180

SF6 rated gage pressure

Mpa 0

 

Product Feature

1. Ideal apparatus in urban and rural electricity network reform : Remote function:remote control, remote metering, remote communication and remote adjustment.

2. Flexible operating: Both power storage and CO operation are motor and manual operated, remote and local operation are both available.

3. Excellent breaking capability: Break short-circuit current 25kA up to 30 times.

4. Small operation power and high dependability: The small motor-driving spring operation mechanism with new design is of lowest operation power (about 30W).

5. Multiple nstallations: Pole mounted and pad mounted.

6. Reliable sealing: The mature sealing technology assures reliable sealing performance

7. Particular incoming and outgoing method: Silicon rubber bushing to make enough insulate distance.

8. Safe operation: Anti-explosive device mounted on the top of box prevents heated gas and maters from spattering out when inner fault occurs.

Ambient condition

1. Altitude: ≤ 2000m

2. Ambient temperature: -40°C~+40°C

3.The wind speed does not exceed 34m / s (equivalent to 700pa on the cylindrical surface)

4. Maximum Temperature Drop: no more than 25°C

5. There will be have dew under the condition of high temperature low down hastily.

 