• Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker
  • Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker
  • Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker
  • Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker
  • Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker
  • Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker

Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: ACB
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
LW8A-40.5
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification
IEC
Transport Package
Wooden Carton
Specification
LW8A-40.5
Trademark
JECSANY
Origin
China
HS Code
8504220000
Production Capacity
50000PCS/Years

Product Description

 

The LW 8A-40.5(W)T2000-31.5 outdoor type SF6 breaker finds its universal range of application for the three-phases electrical system with alternating current 50HZ and the rated voltage 40.5kV.It is used for contolling and protecting the electrical system and measuring the current transformers.
Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker

 

Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit Breaker

Model description

 

 Technical Parameter  

Name Data
Rated voltage 40.5
Rated current(A) 1600/2000
Rated Insulate level Power frequency withstand voltage(kV)1min  95
 Thunder impulse withstand vltage (kV)  185
 Rated short-circuit breaking current(kA)  25/31.5
 Rated outof-phase breaking current (kA)  7.9/10
breaking current of earth fault in different phase(kA)  27.4/34.8
Rated breaking current of single capacitor bank(A)  400
 Rated Operating sequence  O-0.3S-CO-180S-CO
Rated SF6 gas pressure(Mpa)  0.5
Switch-off time(on rated voltage)(ms)  30≤t≤40
Switch-on time(on rated voltage)(ms)  60t80
Rated short-circuit making current(peak) (kA)  63/80
Rated short-circuit duration (s)  4
Rated short-circuit with stand current (kA)  25/31.5 
Rated peak value withstand current(kA)  63/80
Mechanical life (time)  10000

 Cumulative breaking times of rated short-circuit

breaking current 31.5 kA/40kA(time)

 20
 Cumulative breaking times of rated current(time)  2000
Annual leakAge rate of SF6(%)  ≤0.5
Water content of SF6(V\V)(PPm)  ≤150
Outer insulating leakAge ratio distance(mm/kV)  ≥25,≥31
Weight of the circuit breaker(KG)  1000

 


 

Characteristic of structure

1. The LW8-40.5 breaker has the structure which is outdoor porcelain post type. It can be matched with CT35 spring mechanism and has T shape .The circuit breaker is small and light and has good qualities with low operation power, lower noise, high reliability, simple structure. It is also convenient for the operator to install and debug the breaker. The mechanical life is not less than 10000times and the breaker can be operated frequently.

2. The breaker uses pneumatic arc-extinguishing chamber, so the breaking pertormance is excellent and the electrical life can reach up to 20 times. The sealbility is reliable. Static seal uses 0 shape grommet structure, while dynamic seal uses structure of V shape grommet with spring pressure. The secondary terminal block is produced by imported mould according to the pressure injection technologies. So it has high performance of ageing resistance and makes sure that the annual leakAge rate of SF6 < 0.5%. 

3. The metal frame and the support of the circuit breaker are bended with a whole deep steel plate. It used high strength standard accessories and the mechanism is reliable.

4. The measure iron cove of the inner or outer curent transformer is made of materials with the performance of crystallite (alloy) high conduction Magnetic. So the accuracy class can reach up to 0.2 or 0.2S. Every phase of the product can match with 2-4 pieces of current transformers.

Pneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit BreakerPneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit BreakerPneumatic Arc Extinguishing Chamber Outdoor Sf6 3 Phase Circuit BreakerQ: Can we get a sample for reference? 
A: Yes, as long as the goods are conventional type, and you will be charged sample cost plus related shipping cost. Once you place an order to us, we can return or deduct the sample cost to you. 

Q: How to solve the quality problems after sales? 
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days. 

Q: What is the lead time? 
A: The lead time depends on the quantities ordered, generally within 25-35days upon the receipt of advance payment. 

Q: What is your terms of payment ?  
A: We accept West Union, T/T, irrevocable L/C at sight. Prefer T/T 30% deposit before production, the balance against copy of B/L. 

Q: Can you print our brand on the product?
A: Yes, of course, we also do OEM to print client's brand on the product.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now