• Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch
  • Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch
  • Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch
  • Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch
  • Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch
  • Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch

Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch

Type: High-voltage
Structure: Three-column Disconnector
Installation: Outdoor High-voltage
Operation: Manual
Grounding Mode: Not Grounding
Movement Mode: Vertical Rotary Type
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
JS-IACM-24KV-100A
Number of Poles
Three Pole
Grounding
Un Grounded
Series
Three
Run
Turn the Horizontal
Switching Mode
Single Throw-in
Structure of Operating
Manual
Certification
ISO, ISO9001
OEM
According to Customer
Transport Package
Wooden Carten
Specification
HRH-B/11F
Trademark
Jecsany
Origin
China
HS Code
8535309090
Production Capacity
10000PCS/Year

Product Description

Product Description

IACM with polystyrene insulation  Outdoor Load Break Isolate Switch

General

 LBIS Type outdoor on load break switch disconnector contained in this list are destined to switch stub lines and ring main lines or transformers (It can be equipped with MV HRC fuse links as short circuit protection fuction) or for switching under on load conditions. This disconnector complies with IEC/IEEE and DVE-recommendation standards especially comply with DIN VDE 0670 part 3 and IEC 60265, IEC 129.

 Features

 All steels are made of either in stainless steel or hot-dip galvanized steel.

 1. Solid and stable base frame.
 2. main contact with ice protection.
 3. Polymer insulators or alternatively in porcelain.
 4. Minimal sag for the line-connection between two fixed terminals.
 5. Completely maintence antirust Aluminium alloy Arc chamber.
 6. Switching-off procedure without external arc.
 7. Short circuit making capacity under specific conditions possible
 8. Fixing on the supporting structure either by clamping(free setting) or screwing (holes in the   base frame)
 9. Easy on-site installation and setting.

 10. High reliabilty up to 1000 cycles (depending on the running current).

 11. All contacts are either sliver or tin-plated.
 12. Practically maintance-free.

 Environmental   Conditions

 Ambient Temperature: -40ºC - +50ºC 

 Altitude: 2500m

 Frequency: 50Hz / 60Hz

 Maximum Wind Speed: 35m/s

 
Designation Mechanical characteristics

JS-IACM-24KV-50A

A
(mm)

B
(mm)

C
(mm)

D
(mm)
Creepage(HTV Insulator)
(mm)
Number of skirts
(HTV Insulator)
Approximate weight
(Kg)
Reference On isolated Special On isolated Special On isolated Special
On isolated Special
695

695

650

740

884

1020

9

11

80

81
11450 11412
Rated current in continuous service  (A) Rated breaking capacity  (A) Rated short-term admissible current (rms) (kA) (1s) Rated closing capacity on short circuit  ( Crete)(kA) Tension assigned
(kV)
Dry lightning impulsewithstand voltage(kV) Frequency
(Hz)
400 50 12.5 31.5 24 125 50
Designation Mechanical characteristics

JS-IACM-24KV-100A

A
(mm)

B
(mm)

C
(mm)

D
(mm)

H
(mm)
Creepage(HTV Insulator)(mm) Number of skirts (HTV insulator) Approximate weight(Kg)
Reference On isolated Special On isolated Special On isolated Special
On isolated Special
695

695

650

740

640

884

1020

9

11

87

88
14842 14840
Rated current in continuous service  (A) Rated breaking capacity  (A) Rated short-term admissible current (rms) (kA) (1s) Rated closing capacity on short circuit  ( Crete)(kA) Tension assigned
(kV)
Dry lightning impulsewithstand voltage(kV) Frequency
(Hz)
400 100 12.5 31.5 24 125 50

Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch






Isolating Switch 

An electrical device for the reliable disconnection of certain sections of a high-voltage electrical network when there is no current in them. The use of isolating switches (either alone or in combination with high-speed short-circuiting devices) makes it possible to simplify the arrangement of switching points and transformer substations and to eliminate expensive high-voltage circuit breakers.

 

In the case of damage to certain sections of a network, the circuit breakers operate first, and then the isolating switches automatically disconnect the damaged section, after which the circuit breakers close again and restore electric power to the rest of the consumers on the network. Isolating switches are also used to disconnect and reconnect unloaded transformers and sections of power lines during operation. An isolate switch must provide a reliable connection in case of a random occurrence of a short circuit in the network. An important characteristic of an isolating switch is a short operate time, particularly the disconnect time, which must not exceed 0.1 sec.
Iacm with Polystyrene Insulation Outdoor Load Break Isolate Switch